6GK7343-1GX31-0XE0 CP 343-1 Advanced SIMATIC NET

63.882.000 

Communications processor CP 343-1 Advanced for connection of SIMATIC S7-300 CPU to Industrial Ethernet: PROFINET IO controller a./o. IO device; RT and IRT, MRP, PROFINET CBA; TCP/IP, ISO, UDP, S7 comm., S5-compat. communication (SEND/RECEIVE) with Fetch/Write RFC1006, Multicast Diagnostic extension, SNMP, DHCP, FTP client/server, e-mail, Gigabit-SS1X RJ45 (10/100/1000) PROFINET interface 2x RJ45 (10/100 Mbit); PROFINET CBA; security (firewall/VPN); PROFIenergy.

Tải về datasheet (pdf): Tại đây!

6GK7343-1GX31-0XE0 là mô đun mở rộng truyền thông cho PLC S7-300 do hãng SIEMENS phát triển & sản xuất với thương hiệu SIMATIC thuộc họ S7-300. 6GK7343-1GX31-0XE0 được MESIDAS GROUP phát triển và phân phối rộng rãi trên thị trường Việt Nam. Nếu quý khách hàng đang có nhu cầu cần tư vấn hay mua 6GK7343-1GX31-0XE0 thì hãy liên hệ MESIDAS GROUP để được hỗ trợ một cách tận tâm, nhanh chóng và hiệu quả nhé.

6GK7343-1GX31-0XE0

Bảng tóm tắt thông số kỹ thuật 6GK7343-1GX31-0XE0

Communications processor CP 343-1 Advanced for connection of SIMATIC S7-300 CPU to Industrial Ethernet: PROFINET IO controller a./o. IO device; RT and IRT, MRP, PROFINET CBA; TCP/IP, ISO, UDP, S7 comm., S5-compat. communication (SEND/RECEIVE) with Fetch/Write RFC1006, Multicast Diagnostic extension, SNMP, DHCP, FTP client/server, e-mail, Gigabit-SS1X RJ45 (10/100/1000) PROFINET interface 2x RJ45 (10/100 Mbit); PROFINET CBA; security (firewall/VPN); PROFIenergy

Mã sản phẩm 6GK7343-1GX31-0XE0
Dòng sản phẩm SIMATIC S7-300, CP 343-1 Advanced
Hãng sản xuất SIEMENS
Truyền thông RJ45 (10/100/1000)

RJ45 (10/100 Mbit)

Nguồn cung cấp Nguồn ngoài: 24 VDC

Nguồn từ backplane bus: 5 VDC

Kích thước (RxCxS) 80x125x120 mm
Trọng lượng 800 g

Bảng chi tiết thông số kỹ thuật 6GK7343-1GX31-0XE0

Article number 6GK7343-1GX31-0XE0
product type designation CP 343-1 Advanced
transfer rate
transfer rate
● at the 1st interface 10 … 1 000 Mbit/s
● at the 2nd interface 10 … 100 Mbit/s
interfaces
number of interfaces acc. to Industrial Ethernet 3
number of electrical connections
● at the 1st interface acc. to Industrial Ethernet 1
● at the 2nd interface acc. to Industrial Ethernet 2
● for power supply 1
type of electrical connection
● at the 1st interface acc. to Industrial Ethernet RJ45 port
● at the 2nd interface acc. to Industrial Ethernet RJ45 port
type of electrical connection
● for power supply 2-pole plugable terminal block
design of the removable storage
● C-PLUG Yes
supply voltage, current consumption, power loss
type of voltage of the supply voltage DC
supply voltage 1 from backplane bus 5 V
supply voltage external 24 V
supply voltage external at DC rated value 24 V
relative positive tolerance at DC at 24 V 20 %
relative negative tolerance at DC at 24 V 15 %
consumed current
● from backplane bus at DC at 5 V typical 0.14 A
● from external supply voltage at DC at 24 V typical 0.48 A
● from external supply voltage at DC at 24 V maximum 0.62 A
power loss [W] 14.7 W
ambient conditions
ambient temperature
● for vertical installation during operation 0 … 40 °C
● for horizontally arranged busbars during operation 0 … 60 °C
● during storage -40 … +70 °C
● during transport -40 … +70 °C
relative humidity
● at 25 °C without condensation during operation maximum 95 %
protection class IP IP20
design, dimensions and weights
module format Compact module
width 80 mm
height 125 mm
depth 120 mm
net weight 0.8 kg
fastening method
● S7-300 rail mounting Yes
performance data open communication
number of possible connections for open communication by means of SEND/RECEIVE blocks maximum 16
data volume
● as user data per ISO connection for open communication by means of SEND/RECEIVE blocks maximum 8 Kibyte
● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum 8 Kibyte
● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum 8 Kibyte
● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum 2 Kibyte
number of Multicast stations 16
performance data S7 communication
number of possible connections for S7 communication
● maximum 16
performance data multi-protocol mode
number of active connections with multi-protocol mode 48
performance data IT functions
number of possible connections
● as client by means of FTP maximum 10
● as server by means of FTP maximum 2
number of possible connections
● as server by means of HTTP maximum 4
● as email client maximum 1
data volume as user data for email maximum 8 Kibyte
storage capacity of the user memory
● as flash memory file system 28 Mibyte
● as RAM 30 Mibyte
number of possible write cycles of the flash memory cells 100 000
performance data PROFINET communication as PN IO controller
product function PROFINET IO controller Yes
number of PN IO devices on PROFINET IO controller operable total 128
number of PN IO IRT devices on PROFINET IO controller operable 128
number of external PN IO lines with PROFINET per rack 1
data volume
● as user data for input variables as PROFINET IO controller maximum 4 Kibyte
● as user data for output variables as PROFINET IO controller maximum 4 Kibyte
● as user data for input variables per PN IO device as PROFINET IO controller maximum 1 433 byte
● as user data for output variables per PN IO device as PROFINET IO controller maximum 1 433 byte
● as user data for input variables per PN IO device for each sub-module as PROFINET IO controller maximum 240 byte
● as user data for output variables per PN IO device for each sub-module as PROFINET IO controller maximum 240 byte
performance data PROFINET communication as PN IO device
product function PROFINET IO device Yes
data volume
● as user data for input variables as PROFINET IO device maximum 1 024 byte
● as user data for output variables as PROFINET IO device maximum 1 024 byte
● as user data for input variables for each sub-module as PROFINET IO device 240 byte
● as user data for output variables for each sub-module as PROFINET IO device 240 byte
● as user data for the consistency area for each sub-module 240 byte
number of submodules per PROFINET IO-Device 32
performance data PROFINET CBA
number of remote connection partners with PROFINET CBA 64
number of connections with PROFINET CBA total 1 000
data volume
● as user data for digital inputs with PROFINET CBA maximum 8 Kibyte
● as user data for digital outputs with PROFINET CBA maximum 8 Kibyte
● as user data for arrays and data types in the case of acyclic transmission with PROFINET CBA maximum 8 Kibyte
● as user data for arrays and data types with PROFINET CBA with cyclical transfer maximum 250 byte
● as user data for arrays and data types with PROFINET CBA in the case of local interconnection maximum 2 400 byte
performance data PROFINET CBA remote interconnection with acyclic transfer
update time of the remote interconnections in the case of acyclic transmission with PROFINET CBA 100 ms
number of remote connections to input variables in the case of acyclic transmission with PROFINET CBA maximum 128
number of remote connections to output variables in the case of acyclic transmission with PROFINET CBA maximum 128
data volume
● as user data for remote interconnections with input variables in the case of acyclic transmission with PROFINET CBA 8 Kibyte
● as user data for remote interconnections with output variables in the case of acyclic transmission with PROFINET CBA 8 Kibyte
performance data PROFINET CBA remote interconnection with cyclic transfer
update time of the remote interconnections with PROFINET CBA with cyclical transfer 8 ms
number of remote connections to input variables with PROFINET CBA with cyclical transfer maximum 200
number of remote connections to output variables with PROFINET CBA with cyclical transfer maximum 200
data volume
● as user data for remote interconnections with input variables with PROFINET CBA with cyclical transfer maximum 2 000 byte
● as user data for remote interconnections with output variables with PROFINET CBA with cyclical transfer maximum 2 000 byte
performance data PROFINET CBA HMI variables via PROFINET acyclic
number of connectable HMI stations for HMI variables in the case of acyclic transmission with PROFINET CBA 3
update time of the HMI variables in the case of acyclic transmission with PROFINET CBA 500 ms
number of HMI variables in the case of acyclic transmission with PROFINET CBA maximum 200
data volume as user data for HMI variables in the case of acyclic transmission with PROFINET CBA maximum 8 Kibyte
performance data PROFINET CBA device-internal interconnections
number of internal connections with PROFINET CBA maximum 256
data volume of the internal connections with PROFINET CBA maximum 2 400 byte
performance data PROFINET CBA interconnections to constants
number of connections with constants with PROFINET CBA maximum 200
data volume as user data for interconnections with constants with PROFINET CBA maximum 4 096 byte
performance data PROFINET CBA PROFIBUS proxy functionality
product function with PROFINET CBA PROFIBUS proxy functionality No
performance data telecontrol
protocol is supported
● TCP/IP Yes
product functions management, configuration, engineering
product function MIB support Yes
protocol is supported
● SNMP v1 Yes
● SNMP v3 Yes
● DCP Yes
● LLDP Yes
configuration software
● required STEP7 V5.5 SP2 HF1 or higher / STEP 7 Professional V12 (TIA Portal) or higher
● for PROFINET CBA required SIMATIC iMap V3.0 SP4 and higher
identification & maintenance function
● I&M0 – device-specific information Yes
● I&M1 – higher level designation/location designation Yes
product functions diagnostics
product function web-based diagnostics Yes
product functions switch
product feature switch Yes
product function
● switch-managed No
● with IRT PROFINET IO switch Yes
● configuration with STEP 7 Yes
product functions redundancy
product function
● ring redundancy Yes
● redundancy manager Yes
protocol is supported Media Redundancy Protocol (MRP) Yes
product functions security
firewall version stateful inspection
product function with VPN connection IPSec
type of encryption algorithms with VPN connection AES-256, AES-192, AES-128, 3DES-168, DES-56
type of authentication procedure with VPN connection Preshared key (PSK), X.509v3 certificates
type of hashing algorithms with VPN connection MD5, SHA-1
number of possible connections with VPN connection 32
product function
● password protection for Web applications Yes
● ACL – IP-based Yes
● ACL – IP-based for PLC/routing Yes
● switch-off of non-required services Yes
● blocking of communication via physical ports Yes
● log file for unauthorized access No
product functions time
product function SICLOCK support Yes
product function pass on time synchronization Yes
protocol is supported
● NTP Yes
standards, specifications, approvals hazardous environments
certificate of suitability CCC for hazardous zone according to GB standard Yes

Phân phối và báo giá 6GK7343-1GX31-0XE0

Nếu quý khách hàng đang có nhu cầu cần tư vấn hay mua 6GK7343-1GX31-0XE0 thì hãy liên hệ MESIDAS GROUP để được hỗ trợ một cách tận tâm, nhanh chóng và hiệu quả nhé.

5/5 - (1 bình chọn)
Trọng lượng 0,800 kg
Kích thước 8 × 12,5 × 12 cm
Nhận thông báo qua Email
Nhận thông báo cho
guest

Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x